Reliability LNK564GN-TL

2 posts / 0 new

I need the reliability data (FIT rate) for the LNK564GN-TL can you please provide it to me?

Thank you

The failure rate for the LNK564GN-TL is 0.551 FITs (MTBF = 1,814,564,000 hours). This failure rate was estimated by de-rating the high temperature reliability test data to an application use junction temperature of 55°C using an activation energy of 0.7eV and was calculated with a 60% confidence level.